<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>【存储部落】 &#187; SANergy</title>
	<atom:link href="http://www.sansky.net/article/tag/sanergy/feed" rel="self" type="application/rss+xml" />
	<link>http://www.sansky.net</link>
	<description>sansky的存储技术博客，内容涵盖存储解决方案、存储系统、存储硬件、存储软件、存储管理、存储安全、数据备份与恢复、数据保护、存储基础知识，为大家推荐各种存储产品、和存储技术、视频监控、广电、电信、政府、教育、医疗等行业存储系统解决方案，</description>
	<lastBuildDate>Sat, 31 Dec 2011 10:22:25 +0000</lastBuildDate>
	<language>zh-cn</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>SANergy MSCS软件下载及安装说明</title>
		<link>http://www.sansky.net/article/2007-12-02-sanergy-mscs-software-download.html</link>
		<comments>http://www.sansky.net/article/2007-12-02-sanergy-mscs-software-download.html#comments</comments>
		<pubDate>Sun, 02 Dec 2007 05:25:51 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[存储安装配置]]></category>
		<category><![CDATA[下载]]></category>
		<category><![CDATA[软件]]></category>
		<category><![CDATA[MSCS]]></category>
		<category><![CDATA[SANergy]]></category>

		<guid isPermaLink="false">http://www.sansky.net/article/2007-12-02-sanergy-mscs-software-download.html</guid>
		<description><![CDATA[SANergy MSCS是存储共享管理软件SANergy的HA软件。安装了SANergy MSCS的共享存储网络系统可以建立两个MDC服务器，每台服务器之间可实现自动的failover功能，保证存储网络系统的正常运行。 SANergyFS_3.2.7.0.zip SANergy_MSCS_3.2.7.0.zip SANergy MSCS的安装说明请参考：SANergy MSCS HA安装配置指南 如果你在安装的过程中出现问... ]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.sansky.net/article/tag/sanergy" class="st_tag internal_tag" rel="tag" title="标签 SANergy 下的日志">SANergy</a> MSCS是存储共享管理软件SANergy的HA软件。安装了SANergy MSCS的共享存储网络系统可以建立两个MDC服务器，每台服务器之间可实现自动的failover功能，保证存储网络系统的正常运行。</p>
<p><a href="http://www.sansky.net/files/SANergyFS_3.2.7.0.zip" target="_blank"><strong><span style="color: #7da939;">SANergyFS_3.2.7.0.zip</span></strong></a></p>
<p><a href="http://www.sansky.net/files/SANergy_MSCS_3.2.7.0.zip" target="_blank"><strong><span style="color: #7da939;">SANergy_MSCS_3.2.7.0.zip</span></strong></a></p>
<p>SANergy MSCS的安装说明请参考：<a title="SANergy MSCS安装配置指南" href="http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-1.html" target="_blank">SANergy MSCS HA安装配置指南</a></p>
<p>如果你在安装的过程中出现问题，请在本文留言。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-12-02-sanergy-mscs-software-download.html/feed</wfw:commentRss>
		<slash:comments>31</slash:comments>
		</item>
		<item>
		<title>SANergy MSCS HA安装配置指南-4</title>
		<link>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-4.html</link>
		<comments>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-4.html#comments</comments>
		<pubDate>Sun, 14 Oct 2007 11:53:07 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[存储安装配置]]></category>
		<category><![CDATA[存储共享]]></category>
		<category><![CDATA[使用说明]]></category>
		<category><![CDATA[共享软件]]></category>
		<category><![CDATA[cluster]]></category>
		<category><![CDATA[HA]]></category>
		<category><![CDATA[MSCS]]></category>
		<category><![CDATA[SAN]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[Volume]]></category>

		<guid isPermaLink="false">http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha%e5%ae%89%e8%a3%85%e9%85%8d%e7%bd%ae%e6%8c%87%e5%8d%97-4.html</guid>
		<description><![CDATA[4. 故障回复的设置 设置首选所有者在重新启动后是否自动接管集群资源 在群集管理器中Cluster Group组上点右键，选择属性，在弹出的下图所示的窗口中点故障回复页签，选择“允许故障回复” 确定。在SANMDC组上作同样的设置。 完成负载均衡设置， 查看一下设置是否正确。 说明：进行了上述设置后，... ]]></description>
			<content:encoded><![CDATA[<p><strong>4. 故障回复的设置</strong><br />
设置首选所有者在重新启动后是否自动接管集群资源</p>
<p>在群集管理器中Cluster Group组上点右键，选择属性，在弹出的下图所示的窗口中点故障回复页签，选择“允许故障回复”</p>
<p><span id="more-1603"></span></p>
<p><img width="404" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha4-1177cclip-image002.jpg" height="416" /></p>
<p>确定。在SANMDC组上作同样的设置。</p>
<p><img width="404" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha4-1177cclip-image004.jpg" height="416" /></p>
<p>完成负载均衡设置， 查看一下设置是否正确。</p>
<p><img width="553" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha4-1177cclip-image006.jpg" height="227" /><img width="553" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha4-1177cclip-image008.jpg" height="233" /></p>
<p>说明：进行了上述设置后，两台服务器中任何一台的重启都会造成两次资源切换（关机一次，启动一次），而在资源切换过程中数据库和SAN盘阵是无法访问的。因此，根据实际情况需要，这种故障自动回复可以设为防止故障回复。此时，服务器负载均衡需要由系统管理员手动完成。系统管理员手动指定资源的所有者，实现负载均衡，当出现故障时，正常工作的服务器可以将所有资源自动接管，此时另一台服务器可以重启，重启后不会发生资源自动切换。系统管理员可以选择在没有客户端访问请求的时候手动更改某一个资源组的所有者，完成切换，从而不影响正常的业务。</p>
<p><strong>5. 网络映射</strong></p>
<p>网络其他主机要访问SAN上磁盘时需要将虚拟主机SANMDC上共享的磁盘资源 SanDiskShare映射为本地盘符。如图，在网上邻居中找到共享资源后在其上点右键，选择映射网络驱动器，选择适当的驱动器号后，点完成。</p>
<p><img width="391" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha4-1177cclip-image010.gif" height="257" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-4.html/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>SANergy MSCS HA安装配置指南-3</title>
		<link>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-3.html</link>
		<comments>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-3.html#comments</comments>
		<pubDate>Sun, 14 Oct 2007 11:52:58 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[存储安装配置]]></category>
		<category><![CDATA[存储共享]]></category>
		<category><![CDATA[使用说明]]></category>
		<category><![CDATA[共享软件]]></category>
		<category><![CDATA[cluster]]></category>
		<category><![CDATA[HA]]></category>
		<category><![CDATA[MSCS]]></category>
		<category><![CDATA[SAN]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[Volume]]></category>

		<guid isPermaLink="false">http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha%e5%ae%89%e8%a3%85%e9%85%8d%e7%bd%ae%e6%8c%87%e5%8d%97-3.html</guid>
		<description><![CDATA[3. 通过配置实现负载均衡 通过设置虚拟主机，可以实现负载均衡 虚拟主机的建立 群集管理器左侧树结构中组上点右键，选择配置应用程序，点下一步，选择建立一个新的虚拟服务器， 默认，下一步， 输入虚拟主机的名称，下一步 输入虚拟主机IP 下一步 选否 完成 在新建的SANMDC组上点右键，选择联机... ]]></description>
			<content:encoded><![CDATA[<p><strong>3. 通过配置实现负载均衡</strong><br />
通过设置虚拟主机，可以实现负载均衡</p>
<p><strong>虚拟主机的建立</strong></p>
<p>群集管理器左侧树结构中组上点右键，选择配置应用程序，点下一步，选择建立一个新的虚拟服务器，</p>
<p><span id="more-1600"></span></p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image002.jpg" height="362" /></p>
<p>默认，下一步，</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image004.jpg" height="362" /></p>
<p>输入虚拟主机的名称，下一步</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image006.jpg" height="362" /></p>
<p>输入虚拟主机IP</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image008.jpg" height="362" /></p>
<p>下一步</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image010.jpg" height="362" /></p>
<p>选否</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image012.jpg" height="362" /></p>
<p>完成</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image014.jpg" height="362" /></p>
<p>在新建的SANMDC组上点右键，选择联机，激活该资源。</p>
<p><img width="553" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image016.jpg" height="249" /></p>
<p>将CLUSTER GROUP中SANergy磁盘资源和磁盘共享资源拖拽到SANMDC资源组中，本例中为SANDisk和SANDisk_Share资源</p>
<p><img width="553" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image018.jpg" height="249" /></p>
<p>点击是，</p>
<p><img width="434" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image020.jpg" height="119" /></p>
<p>点击是，完成虚拟主机的建立。</p>
<p><img width="399" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image022.jpg" height="211" /></p>
<p><img width="553" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image024.jpg" height="213" /></p>
<p>群集管理器中Cluster Group组上点右键，选择属性，在弹出的下图所示的窗口中点击首选所有者后的修改按钮，选择SERVER1。</p>
<p><img width="404" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image026.jpg" height="396" /></p>
<p>群集管理器中SANMDC组上点右键，选择属性，在弹出的下图所示的窗口中点击首选所有者后的修改按钮，选择SERVER2，通过两个服务器担负不同的任务来实现负载均衡。</p>
<p><img width="404" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha3-11781clip-image028.jpg" height="396" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-3.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SANergy MSCS HA安装配置指南-2</title>
		<link>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-2.html</link>
		<comments>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-2.html#comments</comments>
		<pubDate>Sun, 14 Oct 2007 11:52:57 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[存储安装配置]]></category>
		<category><![CDATA[存储共享]]></category>
		<category><![CDATA[使用说明]]></category>
		<category><![CDATA[共享软件]]></category>
		<category><![CDATA[cluster]]></category>
		<category><![CDATA[HA]]></category>
		<category><![CDATA[MSCS]]></category>
		<category><![CDATA[SAN]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[Volume]]></category>

		<guid isPermaLink="false">http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha%e5%ae%89%e8%a3%85%e9%85%8d%e7%bd%ae%e6%8c%87%e5%8d%97-2.html</guid>
		<description><![CDATA[四、在群集管理器中创建SANergy相关资源 1. 创建 DISK 资源 在群集管理器“组”上点右键，从菜单中选择新建——〉资源， 在名称处填入磁盘的名称 资源类型选择Sanergy Volume 组选择Cluster Group 下一步， 下一步，默认， 填入 被SANERGY管理的磁盘的卷标和序列号，注意没有中间的减号“-”。 2. 建立SAN网络... ]]></description>
			<content:encoded><![CDATA[<p><strong>四、在群集管理器中创建SANergy相关资源</strong><br />
<strong>1. 创建 DISK 资源</strong></p>
<p>在群集管理器“组”上点右键，从菜单中选择新建——〉资源，</p>
<p>在名称处填入磁盘的名称</p>
<p>资源类型选择Sanergy <a href="http://www.sansky.net/article/tag/volume" class="st_tag internal_tag" rel="tag" title="标签 Volume 下的日志">Volume</a></p>
<p>组选择Cluster Group</p>
<p><span id="more-1599"></span></p>
<p><img width="415" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image002.jpg" height="311" /></p>
<p>下一步，</p>
<p><img width="367" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image004.jpg" height="275" /></p>
<p>下一步，默认，</p>
<p><img width="425" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image006.jpg" height="317" /></p>
<p>填入 被SANERGY管理的磁盘的卷标和序列号，注意没有中间的减号“-”。</p>
<p><img width="468" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image008.jpg" height="351" /><br />
<strong>2. 建立SAN网络磁盘的共享资源</strong></p>
<p>在群集管理器“组”上点右键，从菜单中选择新建——〉资源，</p>
<p>在名称处填入磁盘共享的名称</p>
<p>资源类型选择文件共享</p>
<p>组选择Cluster Group</p>
<p><img width="464" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image010.jpg" height="348" /></p>
<p>下一步，</p>
<p><img width="376" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image012.jpg" height="282" /></p>
<p>指定资源依存，（前面SAN网络磁盘资源）</p>
<p><img width="464" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image014.jpg" height="348" /></p>
<p>输入想要给用户看到的共享名称，并指定路径，</p>
<p><img width="467" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image016.jpg" height="350" /></p>
<p>点击完成，配置完成</p>
<p>在刚创建的两项资源上点右键，选择联机，将其激活。</p>
<p>至此，数据库和SANergy MDC的集群设置已经完成，但正常工作时只有一台服务器同时作为数据库和MDC，如果需要做到数据库和MDC的负载均衡，需要作进一步的配置。</p>
<p><img width="553" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha2-11779clip-image018.jpg" height="249" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SANergy MSCS HA安装配置指南-1</title>
		<link>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-1.html</link>
		<comments>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-1.html#comments</comments>
		<pubDate>Sun, 14 Oct 2007 11:48:22 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[存储安装配置]]></category>
		<category><![CDATA[存储共享]]></category>
		<category><![CDATA[使用说明]]></category>
		<category><![CDATA[共享软件]]></category>
		<category><![CDATA[cluster]]></category>
		<category><![CDATA[HA]]></category>
		<category><![CDATA[MSCS]]></category>
		<category><![CDATA[SAN]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[Volume]]></category>

		<guid isPermaLink="false">http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha%e5%ae%89%e8%a3%85%e9%85%8d%e7%bd%ae%e6%8c%87%e5%8d%97-1.html</guid>
		<description><![CDATA[一、在两台服务器上分别安装SANergy软件 先安装SANergy，接管总线， 要被SANERGY管理的磁盘，在Meta Data Controller 中 输入“?CLUS”,被MSCS管理的磁盘，在Meta Data Controller 中 输入“?FREE”, 如下图 SAN ?CLUS heart ?FREE sql ?FREE ?为通配符，?CLUS表示Server1和Server2集群作MDC，管理SAN盘（SAN为被Sanergy管理的盘）。?FREE表示h... ]]></description>
			<content:encoded><![CDATA[<p><strong>一、在两台服务器上分别安装SANergy软件</strong></p>
<p>先安装SANergy，接管总线，</p>
<p><img width="499" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image002.jpg" height="394" /></p>
<p>要被SANERGY管理的磁盘，在Meta Data Controller 中 输入“?CLUS”,被MSCS管理的磁盘，在Meta Data Controller 中 输入“?FREE”,</p>
<p><span id="more-1572"></span></p>
<p>如下图</p>
<p><a href="http://www.sansky.net/article/tag/san" class="st_tag internal_tag" rel="tag" title="标签 SAN 下的日志">SAN</a> ?CLUS</p>
<p>heart ?FREE</p>
<p>sql ?FREE</p>
<p>?为通配符，?CLUS表示Server1和Server2集群作MDC，管理SAN盘（SAN为被Sanergy管理的盘）。?FREE表示heart盘、sql盘不用Server1和Server2来集群管理。</p>
<p>注意：MDC 一定要按照前面说明的进行配置，这一点是与以前安装SANERGY的比较大的区别。</p>
<p><img width="480" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image004.jpg" height="346" /></p>
<p>安装完成后，重启。</p>
<p>重启时资源会自动切换到Server2, 注意重启后应将资源切回到Server1,再在Server1上进行下面的安装。</p>
<p>安装V3.1.2的补丁，重启计算机。</p>
<p>重启后同样要注意资源的切换。</p>
<p><strong>二、在第一台服务器上安装SANergy For <a href="http://www.sansky.net/article/tag/mscs" class="st_tag internal_tag" rel="tag" title="标签 MSCS 下的日志">MSCS</a></strong></p>
<p>注意: 安装前应确保第一台服务器为主控。</p>
<p>在第一台服务器上安装SANERGY FOR MSCS，一路均按默认点击下一步，直到出现下图，选择Cluster Node Setup，按照提示完成安装。</p>
<p><img width="501" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image006.jpg" height="376" /></p>
<p>按同样方法在Server2上安装Sanergy及其补丁，注意，安装前应确保Server2为主控。</p>
<p><strong>三、在第二台服务器上进行SANERGY MSCS的安装</strong></p>
<p>首先更改区码，控制面板——〉区域选项——〉常规页面内将语言设置中西欧和美国设为默认值，点击设为默认值按钮后再弹出的窗口中选择英语（美国），确定后再将下图上方的您的区域设置也变为英语（美国）。</p>
<p><img width="404" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image008.jpg" height="473" /></p>
<p>以上这步必须完成，否则无法在Server2上安装Sanergy MSCS.</p>
<p>重启，使用群集管理器将Cluster Group资源组切换到本机，安装SANERGY MSCS，若此时语言选择默认为英文，说明区码改变正确，否则表明设置有问题。</p>
<p><img width="252" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image010.jpg" height="139" /></p>
<p>一路点击下一步，在下图处选择“Final <a href="http://www.sansky.net/article/tag/cluster" class="st_tag internal_tag" rel="tag" title="标签 cluster 下的日志">Cluster</a> Setup”,</p>
<p><img width="503" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image012.jpg" height="379" /></p>
<p><img width="502" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image014.jpg" height="378" /></p>
<p>点击 Install</p>
<p><img width="305" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image016.jpg" height="245" /></p>
<p>安装完成，点击EXIT，</p>
<p><img width="254" src="http://www.sansky.net/files/2007/10/windowslivewritersanergymscsha1-11670clip-image018.jpg" height="205" /></p>
<p>重启。将系统默认语言和区域选项更改回成中文（简体）和中文（中国）。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-10-14-sanergy-mscs-ha-installation-configuration-guide-1.html/feed</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>SANergy软件下载-存储共享、带宽测试</title>
		<link>http://www.sansky.net/article/2007-10-14-sanergy-software-download-shared-memory-bandwidth-test.html</link>
		<comments>http://www.sansky.net/article/2007-10-14-sanergy-software-download-shared-memory-bandwidth-test.html#comments</comments>
		<pubDate>Sun, 14 Oct 2007 11:15:49 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[带宽]]></category>
		<category><![CDATA[下载]]></category>
		<category><![CDATA[共享软件]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[测试]]></category>

		<guid isPermaLink="false">http://www.sansky.net/article/2007-10-14-sanergy%e8%bd%af%e4%bb%b6%e4%b8%8b%e8%bd%bd-%e5%ad%98%e5%82%a8%e5%85%b1%e4%ba%ab%e3%80%81%e5%b8%a6%e5%ae%bd%e6%b5%8b%e8%af%95.html</guid>
		<description><![CDATA[SANergy软件功能： 1、文件系统共享： 在IPTV、网络视频、广电制作网、石油气象高性能计算等系统中，软件应用需要多个主机能同时对一个共享文件系统（共享卷）进行读写访问。由于SAN存储本身是裸设备，没有NAS的网络共享功能，为了实现存储的逻辑卷（LUN）可在多台主机间实现文件系统级共享，就... ]]></description>
			<content:encoded><![CDATA[<p>SANergy软件功能：</p>
<p>1、文件系统共享：</p>
<p>在IPTV、网络视频、广电制作网、石油气象高性能计算等系统中，软件应用需要多个主机能同时对一个共享文件系统（共享卷）进行读写访问。由于SAN存储本身是裸设备，没有NAS的网络共享功能，为了实现存储的逻辑卷（<a href="http://www.sansky.net/article/tag/lun" class="st_tag internal_tag" rel="tag" title="标签 LUN 下的日志">LUN</a>）可在多台主机间实现文件系统级共享，就需要用到<a href="http://www.sansky.net/article/2007-05-12-san-network-storage-sharing-software-place.html" target="_blank">SAN网络存储共享管理软件</a>。</p>
<p>类似的软件还有ImageSAN、<a href="http://www.sansky.net/article/2007-05-12-stornext-sanergy.html" target="_blank">StorNext</a>、GPFS、CXFS等。</p>
<p>2、存储设备<a href="http://www.sansky.net/article/2007-05-28-iometer.html" target="_blank">性能测试</a>：</p>
<p>大家可能经常会用IOmeter软件来进行存储设备的性能。其实，SANergy软件除了主要的文件系统共享功能之外，还内嵌了强大的测试功能。</p>
<p>建议：</p>
<blockquote><p>一般测试IOPS用<a href="http://www.sansky.net/index.php?dl_id=28" target="_blank">IOMETER</a>（小文件），</p>
<p>测试带宽性能建议用SANERGY（大文件）。</p>
<p>测试前要简单分心应用系统的访问方式（数据库类访问、文件读取访问和是流媒体访问，确定系统文件的大小），再选择测试工具软件。</p></blockquote>
<p>试用版SANergy for windwos软件，经全国人民验证与正版没有什么区别，不需要注册码，也没有使用时间限制。</p>
<p>注：安装过程中有一个语言包的选择，由于没有中文包，大家安装英文版就行，界面很简单。</p>
<p><strong></strong></p>
<p>发现好多我发给朋友们的邮件在几天后有退信的现象，也不知道他们收到没有，加上我这一段时间比较忙，可能无法在很短的时间内回复邮件，我改成了在线下载方式，有需要的朋友可以直接点击下面的链接来下载.</p>
<p><strong></strong><br />
<a href="http://www.sansky.net/files/SANergyFS_3.2.7.0.zip" target="_blank"><strong>SANergyFS_3.2.7.0.zip</strong></a></p>
<p><a href="http://www.sansky.net/files/SANergy_MSCS_3.2.7.0.zip" target="_blank"><strong>SANergy_MSCS_3.2.7.0.zip</strong></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-10-14-sanergy-software-download-shared-memory-bandwidth-test.html/feed</wfw:commentRss>
		<slash:comments>142</slash:comments>
		</item>
		<item>
		<title>媒体发表：SAN网络存储共享软件全攻略</title>
		<link>http://www.sansky.net/article/2007-08-29-media-san-network-storage-sharing-software-place.html</link>
		<comments>http://www.sansky.net/article/2007-08-29-media-san-network-storage-sharing-software-place.html#comments</comments>
		<pubDate>Wed, 29 Aug 2007 15:40:59 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[快乐生活]]></category>
		<category><![CDATA[存储共享]]></category>
		<category><![CDATA[软件]]></category>
		<category><![CDATA[ImageSAN]]></category>
		<category><![CDATA[SAN]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[StorNext]]></category>
		<category><![CDATA[文件系统]]></category>

		<guid isPermaLink="false">http://www.sansky.net/html/2007-08-29-1306.html</guid>
		<description><![CDATA[在高性能专用存储网络需求的驱使下，SAN存储区域网络系统大量应用于高性能计算网络系统、大型网站系统、非线性编辑系统等网络系统中，存储设备与计算机主机系统之间一对一的关系，被可供多个系统共享同一个存储设备网络的关系所取代。为确保多大量客户端主机对同一存储设备的共享访问权限... ]]></description>
			<content:encoded><![CDATA[<p>在高性能专用存储网络需求的驱使下，SAN存储区域网络系统大量应用于高性能计算网络系统、大型网站系统、非线性编辑系统等网络系统中，存储设备与计算机主机系统之间一对一的关系，被可供多个系统共享同一个存储设备网络的关系所取代。为确保多大量客户端主机对同一存储设备的共享访问权限和和管理权限的统一，就需要安装专门的存储共享管理软件或采用专门的共享文件系统。<a href="http://www.sansky.net/article/tag/sanergy" class="st_tag internal_tag" rel="tag" title="标签 SANergy 下的日志">SANergy</a>、<a href="http://www.sansky.net/article/tag/imagesan" class="st_tag internal_tag" rel="tag" title="标签 ImageSAN 下的日志">ImageSAN</a>、<a href="http://www.sansky.net/article/tag/stornext" class="st_tag internal_tag" rel="tag" title="标签 StorNext 下的日志">StorNext</a>、GPFS、CXFS等软件或文件系统就是为了实现存储设备共享而开发的</p>
<p>发表地址：</p>
<p><a href="http://www.dostor.com/a/implement/2007-04-19/0003232558.shtml">http://www.dostor.com/a/implement/2007-04-19/0003232558.shtml</a></p>
<p>抓图如下：</p>
<p><a rel="lightbox" href="http://www.sansky.net/files/2007/08/118840204191-clip-image001.jpg" title="片段_5"><img border="0" width="587" src="http://www.sansky.net/files/2007/08/118840204191-clip-image001.jpg" alt="片段_5" height="610" id="urn:zoundry:jid:118840204191_clip_image001.jpg" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-08-29-media-san-network-storage-sharing-software-place.html/feed</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>案例：盘阵故障分析</title>
		<link>http://www.sansky.net/article/2007-06-28-arroy-troubleshooting.html</link>
		<comments>http://www.sansky.net/article/2007-06-28-arroy-troubleshooting.html#comments</comments>
		<pubDate>Thu, 28 Jun 2007 15:04:03 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[基础知识]]></category>
		<category><![CDATA[存储控制器]]></category>
		<category><![CDATA[CHKDSK]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[SCSI]]></category>
		<category><![CDATA[文件系统]]></category>
		<category><![CDATA[数据库]]></category>
		<category><![CDATA[故障诊断]]></category>

		<guid isPermaLink="false">http://www.sansky.net/html/2007-06-28-1113.html</guid>
		<description><![CDATA[网友： 我一个学医的，可被领导派到专门负责计算机。我是什么都不懂啊，只知道装个系统，杀个毒。出了什么问题也只有干着急。最近磁盘阵列出了问题，去哪问，人家都不清楚，今天找到这个好地方，希望这里好心的老师们能帮帮我，谢谢了。 我用的是豪威科技公司代理的台湾公司出的Simbolo SCSI... ]]></description>
			<content:encoded><![CDATA[<p>网友：</p>
<p>我一个学医的，可被领导派到专门负责计算机。我是什么都不懂啊，只知道装个系统，杀个毒。出了什么问题也只有干着急。最近磁盘阵列出了问题，去哪问，人家都不清楚，今天找到这个好地方，希望这里好心的老师们能帮帮我，谢谢了。<br />
我用的是豪威科技公司代理的台湾公司出的Simbolo SCSI系列的SB-2990D磁盘阵列。<br />
我一菜鸟，具体问题细节说不大清楚，就随便讲点重点：磁盘阵列做了两个RAID，每个都是5块硬盘。一个放的是数据库，访问量不大，一个放的是视频点播，访问量稍微大，但也顶多50人同时在线。上两个月用的时候，隔个什么三，四天偶尔出个问题，重启就好了，可从上个星期开始，开机没几个小时，服务器就开始弹“磁盘写入还是读取失败或是网络失去连接之类的，数据无法保存到某某”(具体错误提示见下图)，出现这个提示后，磁盘阵列的E盘和F盘就无法访问了，然后我重启磁盘阵列，再重启服务器，好啦，数据都还正常。可过不了几个小时，就又出现这个提示，根本没法用啊。没办法，我把访问量稍大的视频点播关了，只开数据库，咦，管了两天，今天又开始出错了（数据库一天才10来个人访问啊）。<span id="more-1113"></span><br />
　　想起两个细节，一是自从频繁出现这种问题后，我发现磁盘阵列上的10块硬盘灯有时会同时闪，或是一边的5个先闪，在另边的5个再闪。而且闪的时候并没有任何人访问硬盘上的数据，有时我把网线拔了仍有闪的情况。二是弹出这个错误框后，我设置控制器准备重启磁盘阵列时，经常会闪出“FAIL FAN”的提示，但马上又消失。以前好的时候从没发现FAIL FAN的提示。<br />
再具体点的东西我也谈不出来了，本人实在太菜，请各位老师能提出简单有效的解决方案。谢谢了。<br />
<img border="0" width="491" src="http://www.sansky.net/wp-content/2007/06/windowslivewriter8bc0c50cfe6d-14358clip-image001.jpg" height="329" /></p>
<p>Sansky：</p>
<p>1、经常会闪出“FAIL FAN”的提示？<br />
有可能是风扇出问题了，<br />
2、图中给出的提示一般是系统的文件系统的MFS出问题了，可以用WINDOWS系统自带的工具查一下，进入命令行窗口，运行chkntfs  D：”  ，D表示“\movie\港台”文件夹所在盘符，如提示有问题，可用chkdsk D:/x命令来进行修复，由于在进行此操作时，系统必须将D盘先卸载，因此之操作必须在没有应用请求的情况下进行，当然也可以很简单在在存储阵列开机的情况下，重启服务器，服务器在重启的过程会会自动修复文件系统的错误，<br />
3、在没有报警声（除非你的设备的报警系统坏了）的前提下，存储卷所对应的硬盘同时闪灯，一般都表示存储系统按到到访问请求。即使只有一台服务器与存储设备连接，偶尔也会出现闪灯的情况，这是正常的。<br />
一般情况下，硬盘的灯为绿色，长亮表示没有数据读写，快闪表示有数据读写。当灯变为红色、黄色、或橙色，一般都表示有问题。当然各家设备对灯色的定义也不一定相同，你可以用存储设备管理软件查看一下，是否有diskfail、offline等错误信息，然后再做决定。</p>
<p>网友：</p>
<p>谢谢sansky老师的回答。<br />
1、经常会闪出“FAIL FAN”的提示？<br />
有可能是风扇出问题了，<br />
请问风扇问题有可能是引发阵列延缓写入失败的原因吗？还有风扇问题，我该如何解决呢？除尘吗？上半年阵列没有放在机柜里，确实有点脏。<br />
2、图中给出的提示一般是系统的文件系统的MFT文件出问题了，可以用WINDOWS系统自带的工具查一下，进入命令行窗口，运行chkntfs  D：”  ，D表示“\movie\港台”文件夹所在盘符，如提示有问题，可用chkdsk D:/x命令来进行修复，由于在进行此操作时，系统必须将D盘先卸载，因此之操作必须在没有应用请求的情况下进行，当然也可以很简单在在存储阵列开机的情况下，重启服务器，服务器在重启的过程会会自动修复文件系统的错误，<br />
只要弹出了类似这样的提示，磁盘阵列就无法访问了。但类似这样的错误提示并没有局限在哪个文件夹，好像是出错后，用户访问服务器上的数据在哪个文件夹，就会弹出这个。也确实是重启后就恢复正常了，但往往管不了多长时间，又出问题。好像经不起访问似的。<br />
3、在没有报警声（除非你的设备的报警系统坏了）的前提下，存储卷所对应的硬盘同时闪灯，一般都表示存储系统按到到访问请求。即使只有一台服务器与存储设备连接，偶尔也会出现闪灯的情况，这是正常的。<br />
（没有报警声，报警系统也没坏）不是那种显示错误的灯再闪。阵列开机，不是要检测硬盘灯会闪吗。就是那种类似闪法。偶尔会闪一下。我奇怪的是没有人访问阵列，为什么会闪，而且是同时闪。为什么以前没有呢。</p>
<p>Sansky：</p>
<p>问题1：风扇有可能已经不转了，或者转速不足，或风扇的供电系统出现故障，时转时不转，可以换一个风扇试试。<br />
问题2：有两种可能:<br />
第一种是盘阵到服务器的链路有问题，连接不稳定，数据无法正常的写入存储卷。可以查看一下盘阵的SCSI接口、SCSI线、SCSI卡等是否松动，有可能的话将这些重新插一次，保证所有部件都连接安装好。<br />
第二种可能是盘阵的两个卷与两个服务器之间的共享问题，原因是有两个或两个以的服务器对同一个存储卷具有控制权限（即有分区、格式化等权限），每台服务器都会在存储卷中写入一个文件系统信息（每个存储卷或盘的文件系统信息是写在该盘的0道，而不是写在服务器的系统盘里），从来引起卷的文件系统出错。当服务器检测到自己写入存储卷中的文件系统信息已经破坏时，就会提示进行磁盘修复，并在存储卷的根目录下创建一个名称以found000开头的文件夹,并将已经破坏的文件索引信息对应的文件转移该文件夹下，这时正在进行的读写操作就会停止，并给出如图所示的错误信息。存储卷的根目录一出现以found000为开头的文件夹就表示该卷的文件系统已损坏，必须用chkdsk D:/x进行磁盘修复或重启系统进行自动修复，修复完成后，found000文件夹中的文件会重新回到原来的路径下。<br />
解决的方案如下：<br />
      1）如果两台服务器上安装有sanergy等存储共享软件，那么盘阵的两个控制既可连接到一个服务器上，也可分别连接到不同的服务器上。<br />
      2）如果两台服务器上没有安装sanergy等存储共享软件，且盘阵支持mapping功能，可在盘阵上设置一个服务器只能“看到”一个卷，然后将两个控制器分别连接到不同的服务器上。否则只能将两个控制器连接到一个服务器上，再在服务器上共享该服务器将“看到”的两个存储卷，另一个服务器和别的工作站通过网络来访问存储卷。<br />
问题3：闪灯<br />
按我自己的工作经验，讲述一下在先启动盘阵后启动服务器的整个过程中盘阵的闪灯情况。<br />
第一步，启动盘阵。盘阵在开机时，一般来说，所有硬盘灯先是橙色快闪几下，然后绿色慢闪几下（电源系统检测），接下来，每个硬盘分别绿色慢闪（进行校验），每个硬盘都通过后，所有硬盘再绿色快闪几下，几秒种后，若没有报警声，或个别硬盘灯变色，则表示整个盘阵系统正常。<br />
第二步，服务器开机后，进行硬件设备检测时，盘阵上的硬盘灯一般会绿色快闪两三下，表示系统已经检测到盘阵。接下来，进入系统时，磁盘管理系统会进行磁盘检测、文件系统检测，检测磁盘中保存的文件系统信息，并进行核对，这时盘阵会绿色快闪几下（如果注意过普通工作站的开机过程，也会发现硬盘灯闪的现象）。如果发现文件系统信息已发生更改，操作系统会提示是否进行修复（普通工作站突然掉电重启时，操作系统有时也会有这样的提示）。<br />
第三步，进入系统，系统每隔一段时间会检测所连接到设备，检测设备的连接是否正常，就也就是盘阵为何会偶尔闪一两下的原因。<br />
第四步，读写数据，对一个卷进行数据读写时，组成该卷的所有硬盘一般都会快闪，闪的时间与读写需要的时间相同。<br />
以上是从开机到进行数据读写时步骤，不同的盘阵开机的表现可能略有不同。<br />
当一个硬盘发生故障或offline时，该硬盘会一直保持橙色慢闪或红色慢闪，一般会有报警声。对应的卷还可以进行读写，只是读写效率会有不现程度的降低。<br />
当多个硬盘发生故障或offline时，一般对应卷中的所有硬盘都会橙色慢闪或红色慢闪，有报警声，无法进行读写操作。</p>
<p>网友：</p>
<p>再次谢谢sansky老师的回答。我昨天把阵列搬出来除了尘，各种线卡也重新插了插。然后开机到今天上午都没出什么问题，但下午刚才又出现了上面的那种提示。我回想了一下，刚才机房在上课，学生们都在学习使用数据库，所以阵列的访问量大了。<br />
我的阵列目前只接了一台服务器。但是是一个控制器控制两个RAID，去年有一个控制器坏了。我感觉，好象不管哪一边的RAID只要访问量一过大（其实也不大，相对而说），或是两个RAID同时有人频繁访问，就会出错。重启阵列后就正常。<br />
（还有个细节，我的服务器里面好象没看见RAID卡，是一根数据线接在主板上，再插到阵列上的，我们系统管理员出去读书了，是他做的，我也搞不懂，唉！）</p>
<p>Sansky：</p>
<p>应该与访问量的大小没关系，首先，数据库的访问主要是I/O请求数，所需要的带宽其实很小，每次请求的数据一般只有几K。当然你可以测试一下阵列能提供的总带宽，可用sanergy软件，也可手工拷贝一个大文件按所用时间来计算带宽。</p>
<p>有可能是硬盘有问题，不知道你那个阵列有没有硬盘性能方面的监控软件，还有，如果是硬盘的问题，系统的曰志里会有报错信息，提示你某个卷的drive 2或drive 3有问题，</p>
<p>还有你用的产品我还见过，我没用过国产的东西，最好的解决办法还是咨询厂家。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-06-28-arroy-troubleshooting.html/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>非线性编辑制作系统存储扩容方案</title>
		<link>http://www.sansky.net/article/2007-05-12-video-edit.html</link>
		<comments>http://www.sansky.net/article/2007-05-12-video-edit.html#comments</comments>
		<pubDate>Sat, 12 May 2007 15:26:53 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[存储技术]]></category>
		<category><![CDATA[存储共享]]></category>
		<category><![CDATA[下载]]></category>
		<category><![CDATA[网络存储]]></category>
		<category><![CDATA[非线性编辑]]></category>
		<category><![CDATA[解决方案]]></category>
		<category><![CDATA[FC]]></category>
		<category><![CDATA[ImageSAN]]></category>
		<category><![CDATA[ISCSI]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[StorNext]]></category>

		<guid isPermaLink="false">http://www.sansky.net/?p=204</guid>
		<description><![CDATA[与Fiber Channel（以下简称FC）一样，iSCSI也可以做在非线性编辑制作网络系统中SAN网络存储系统架构中，以共享的方式给网络中所有主机提供数据存储服务。两者都必须采用SANergy、StorNext、ImageSAN等存储共享管理软件来实现存储共享卷的管理和访问权限控制，都必须采用一台或多台存储共享管理服务器，... ]]></description>
			<content:encoded><![CDATA[<p>与Fiber Channel（以下简称FC）一样，iSCSI也可以做在非线性编辑制作网络系统中SAN网络存储系统架构中，以共享的方式给网络中所有主机提供数据存储服务。两者都必须采用SANergy、<a href="http://www.sansky.net/article/tag/stornext" class="st_tag internal_tag" rel="tag" title="标签 StorNext 下的日志">StorNext</a>、ImageSAN等存储共享管理软件来实现存储共享卷的管理和访问权限控制，都必须采用一台或多台存储共享管理服务器，采用Block协议方式来传输数据。</p>
<p>点击下载完整方案：<a href="http://www.sansky.net/files/200661291803.zip" title="下载">下载</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-05-12-video-edit.html/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>选择视频编辑网络系统存储设备的要点</title>
		<link>http://www.sansky.net/article/2007-05-12-testing.html</link>
		<comments>http://www.sansky.net/article/2007-05-12-testing.html#comments</comments>
		<pubDate>Sat, 12 May 2007 15:13:48 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[存储技术]]></category>
		<category><![CDATA[容量]]></category>
		<category><![CDATA[带宽]]></category>
		<category><![CDATA[码率]]></category>
		<category><![CDATA[网络存储]]></category>
		<category><![CDATA[非线性编辑]]></category>
		<category><![CDATA[FC]]></category>
		<category><![CDATA[IOmeter]]></category>
		<category><![CDATA[LUN]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[测试]]></category>

		<guid isPermaLink="false">http://www.sansky.net/?p=200</guid>
		<description><![CDATA[对于一个视频系统中的存储设备来讲，最主要的功能不是存储容量，而是支持多个终端上的视频流实时写入或进行实时播放，存储设备对外提供的带宽越大，能支持实时写入和在线播放的视频流数或终端数就越多，视频系统的性能就越高。 因此在选择视频系统的存储设备时，第一要考虑的是存储设备... ]]></description>
			<content:encoded><![CDATA[<p>对于一个视频系统中的存储设备来讲，最主要的功能不是存储容量，而是支持多个终端上的视频流实时写入或进行实时播放，存储设备对外提供的带宽越大，能支持实时写入和在线播放的视频流数或终端数就越多，视频系统的性能就越高。</p>
<p>因此在选择视频系统的存储设备时，第一要考虑的是存储设备能提供的带宽，如果提供的带宽不足，就直接决定了这个存储设备不能用。其次考虑的才是存储设备的安全性、故障恢复和数据备份等方面的性能。<span id="more-200"></span></p>
<p>视频文件的码率是相对固定的，网络的带宽足够时，视频播放时画面才会流畅。因此要求存储设备提供的带宽不是其指其它最大带宽，而是指恒定带宽。只有恒定带宽大，支持的视频流数量才会大。</p>
<p>存储设备厂家提供给大家一般都是通过SANERGY软件或IOMETER等软件测试出来的数值，而这两个软件测试出来的数值都是一个平均值(1秒内的)。这个数据往往与实际可用的恒定带宽有较大的差距，因此不可将这个数据做为评定存储设备性能的参考值，更不能直接应用在视频行业的存储设备设计中。存储设备的实际可用恒定带宽必须经过视频流播放或写入测试才能获得。</p>
<p>目前国内几个专业的视频行业集成商，他们选用的存储设备都是通过测试合格的设备。无论是哪个厂家提供的新设备或新型号，都需要搭建实际的应用环境专门进行读写性能测试。测试的主要项目为：<br />
1、多台工作站同时读一个文件，<br />
2、多台工作站同时写入一个卷或从一个卷上读取多个文件，<br />
3、多台工作站同时写入多个卷，或从多个卷上读取文件，<br />
4、一部分工作站先进行一个卷的读写，等该卷支持的稳定读写视频流达到最大值后，另一部分工作站再进行第二个卷的读写。<br />
5、在多个视频流稳定读写的过程中，模拟存储设备的控制器、硬盘、电源等设备要故障时对最大视频流数量的变化。<br />
6、。。。。。。。</p>
<p>由于现在的存储设备所能提供的带宽大越来越大，要想测试出存储设备带宽的最大值，就需要搭建的模拟网络环境也越来越大，往往需要几十台甚至上百台工作站。而一台工作站往往都要十几万，因此测试时仅占用设备的费用就需要成百上千万。在人力方面，需要5-10人，前后共一个月的时间。因此即使是国内最大的视频网络系统集成商索贝公司都越来越没有能力单独进行这种大型的测试了。不过因为索贝公司所承接的网络系统都比较大，工作站数量比较多，才可能会在项目施工的过程穿插做一些新设备或软件的专项测试。或者在一些大客户的协调和组织下，联合中科大洋公司一起做一些大型测试。</p>
<p>目前国内算得大型的两次存储设备测试都是由CCTV组织的，我很幸运地参与过一次，独立负责过一次。</p>
<p>另外，我要说明的是，视频编辑网络一般会采用FC+以太的SAN双网结构。而现在，随着NAS服务器系统的对存储管理能力的加强，TOE卡投入实际的应用，通过链路聚合将多个网卡绑定在一起来NAS服务器对外提供更大的连接带宽，基于千兆网的单网结构也可以应用在视频行业，不过由于NAS服务器对外提供的带宽只有40-60M左右，因此NAS还之能应用在小型的，或视频流码率较小的视频系统中。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-05-12-testing.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Stornext 与SANergy软件对比</title>
		<link>http://www.sansky.net/article/2007-05-12-stornext-sanergy.html</link>
		<comments>http://www.sansky.net/article/2007-05-12-stornext-sanergy.html#comments</comments>
		<pubDate>Sat, 12 May 2007 14:49:10 +0000</pubDate>
		<dc:creator>sansky</dc:creator>
				<category><![CDATA[存储技术]]></category>
		<category><![CDATA[精华推荐]]></category>
		<category><![CDATA[下载]]></category>
		<category><![CDATA[产品对比]]></category>
		<category><![CDATA[软件]]></category>
		<category><![CDATA[SANergy]]></category>
		<category><![CDATA[StorNext]]></category>
		<category><![CDATA[文件系统]]></category>

		<guid isPermaLink="false">http://www.sansky.net/?p=194</guid>
		<description><![CDATA[StorNext FS 是完全为SAN 网络环境设计的文件系统，不依赖于任何现有操作系统中附带的文件系统。SANergy 不是一个独立的文件系统，它截取文件I/O 重定向到MDC 文件系统管理的磁盘，所以它只是一个SAN 文件系统外壳软件。 点击下... ]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.sansky.net/article/tag/stornext" class="st_tag internal_tag" rel="tag" title="标签 StorNext 下的日志">StorNext</a> FS 是完全为SAN 网络环境设计的文件系统，不依赖于任何现有操作系统中附带的文件系统。<a href="http://www.sansky.net/article/tag/sanergy" class="st_tag internal_tag" rel="tag" title="标签 SANergy 下的日志">SANergy</a> 不是一个独立的文件系统，它截取文件I/O 重定向到MDC 文件系统管理的磁盘，所以它只是一个SAN 文件系统外壳软件。</p>
<p>点击<a href="http://www.sansky.net/files/stornext-and-sanergy.zip" title="stornext-and-sanergy.zip">下载</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.sansky.net/article/2007-05-12-stornext-sanergy.html/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
	</channel>
</rss>

